  page 1 of 10 ? slim profle, for din-rail mounting ? alternative side-mounting for fat panels ? high power factor by active power correction ? very high effciency up to 94.5% ? back power immunity ? 150% peak current for 4 sec. ? operating temperature range: C25c to +70c max. ? adjustable output voltage ? dcCok indicator ? short circuit and overload protection this generation of din-rail power supplies combines the most effcient circuit topology with optimized cost/performance ratio for industrial environments and for electrical control cabinets. they have a very high effciency of up to 94.5% which allows a very slim pack - age design. the case offers the potentially useful feature to fx the din-rail clip to the side wall for the mounting inside fat panels. over a period of minimum 4 seconds they can operate with a boost power of 150%. the boost power facili - tates the activation of stepper motors, solenoids or actuators. the units operate with a high power factor of up to 99% by active power factor correction which also keeps the input inrush current low. the tib series models are available with a nominal power of 80, 120, 240 or 480 watt (+50% boost power). the output voltage is adjustable from 23.5 to 28 vdc. they come with the safety standard approvals for iec/en 60950-1, ul 60950-1 and ul 508. order code output power (max.) output voltage nom. (adjustable) output current (max.) effciency (typ.) tib 080-124 80 w 24 vdc (23.5C28) 3.4 a 90.0 % tib 120-124 120 w 24 vdc (23.5C28) 5.0 a 93.5 % tib 240-124 240 w 24 vdc (23.5C28) 10 a 94.5 % tib 480-124 480 w 24 vdc (23.5C28) 20 a 94.7 % models ul 50 8 cb scheme ul60 95 0- 1 http://www.tracopower.com industrial power supplies tib series, 80 C 480 w
page 2 of 10 all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. input specifications input voltage C nominal ranges 100 C 240 vac C effective ranges 85 C 264 vac (below 90 vac a derating of 3%/v is required) input voltage frequency 45 C 65 hz standby power cunsumption 80 w model: 0.9/1.3 w (115 / 2 3 0 va c ) 120 w model: 1.9/1.6 w (115 / 2 3 0 va c ) 240 w model: 1.7/1.9 w (115 / 2 3 0 va c ) 480 w model: 3.8/3.8 w (115 / 2 3 0 va c ) power factor correction (pfc) 80 w model: 0.48/0.48 (115 / 2 3 0 va c ) 120 w model: 0.97/0.8 (115 / 2 3 0 va c ) 240 w model: 0.98/0.92 (115 / 2 3 0 va c ) 480 w model: 0.99/0.97 (115 / 2 3 0 va c ) harmonic limits C acc. en 61000-3-2 80 w model: class a 120C480 w models: class a, b, c, d inrush current 15/30 a max. (115 / 2 3 0 va c ) output specifications output voltage adjustment 1) 23.5 C 28.0 vdc regulation C input variation 0.1 % max. C load variation (10C90 %) 0.5 % max. temperature coefficient 0.02 %/k hold-up time 80 w model: 20/160 ms min. (115 / 2 3 0 va c ) 120C480 w models : 20 ms min. start-up time 2 s max. ripple and noise (20mhz bandwidth) 100 mvp-p max. output overvoltage protection (ovp) 2) 80C240 w models: 32 C 35 v 480 w model: 29 C 30 v power back immunity 3) < ovp level operation C nominal operation 100 % of iout nom. C peak power operation 105 C 150 % of iout nom. C constant current (cc) 155 % of iout nom. duty cycle 4) C threshold > 105 % (for peak and cc mode) C cc or peak opeartion timer 4 s max. (switch off) C normal operation / off period < 10 s (automatic restart after switch off or peak and cc operation timer reset) short circuit switch off after 4s delay, automatic restart dc ok signal C dc on vout > 22.5 v typ. relay contact closed, max. 1 a, < 100mohm C dc off vout < 21.5 v typ. relay contact open, max 30 v 1) output voltage can be adjusted as indicated. however, output power has to be maintained at nominal value. this means the output nominal current has to be reduced in accordance with the increase of output voltage. 2) in case of an internal error a second voltage regulation loop keeps the output voltage at a save level, the power supply turns off and restarts after 10 seconds. 3) when external voltage is supplied above set output voltage and below ovp threshold, the power supply will function normally without switch off or destruction, even if external voltage is applied continuously. 4) in case of overload or short circuit, the unit switches the output voltage off after 4 seconds and tries to restart every 10 seconds. http://www.tracopower.com tib series, 80 C 480 w
page 3 of 10 general specifications operating temperature C25c to +70c max. derating above +60oc : 2.0%/k cooling convection cooling, no internal fan overtemperature protection switch off at overtemperature humidity (non condensing) 5C95 % rel. h max. altitude during operation 2000 m max. isolation voltage C input/ouput 4250 vdc C input/chassis 1500 vdc C ouput/chassis 750 vdc creapage clearance C input/ouput 8 mm C input/chassis 4 mm C output/chassis 1.5 mm mtbf (acc. to iec 61709 at 25c) 80 w model: > 1950000 h 120 w model: > 1450000 h 240 w model: > 1300000 h 480 w model: > 1000000 h safety standards C information technology equipment iec/en 60950-1, ul 60950-1 csa 22.2 no 60950-1-03 C safety low voltage switchgear and controlgear ul 508 C certification documents www.tracopower.com/overview/tib electromagnetic compatibility (emc), emissions en 61000-6-3, en 61204-3 C conducted ri suppression on input en 55022, en 55011 class b, C radiated ri suppression en 55022, en 55011 class b, electromagnetic compatibility (emc), immunity en 61000-6-2, en 61204-3 C electrostatic discharge (esd) iec/en 61000-4-2 4 kv/8 kv criteria a C radiated rf field immunity iec/en 61000-4-3 10 v/m criteria a C electrical fast transient / burst immunity iec/en 61000-4-4 2 kv criteria b C surge immunity iec/en 61000-4-5 1 kv/2 kv criteria b C immunity to conducted rf disturbances iec/en 61000-4-6 10 v criteria a C power frequency field immunity iec/en 61000-4-8 30 a/m criteria a C mains voltage dips and interruptions iec/en 61000-4-11 criteria b/c C voltage sag immunity semi f47 environment C vibration acc. iec 60068-2-6-3 3 axis, 2 g sine sweep, 10C55 hz, 11 okt/min C shock acc. iec 60068-2-27 3 axis, 25 g half sine, 11 ms enclosure material C chassis aluminium C cover stainless steel mounting C din-rail mounting for din-rails as per en 50022-35x15/7.5 environmental compliance C reach www.tracopower.com/products/reach-declaration.pdf C rohs rohs directive 2011/65/eu connection screw terminals remote on/off the unit can be controlled by external relay (480 w model only) contact or open collector signal. C contact rating open: 15 v; leakage current max 100 a close: 0.3 v; max drop at 15 ma C signal assignement o n = open o f f = c l o s e d 1 2 3 1 3 2 o n = l o w o f f = h i g h o n = h i g h o f f = l o w 1 2 3 1 2 3 o n = closed o f f = open normal operation reversed operation normal operation reversed operation http://www.tracopower.com tib series, 80 C 480 w
page 4 of 10 block diagrams function specification circuit block diagram for tib 80, wide range flyback circuit block diagram for tib 120 and tib 240 http://www.tracopower.com tib series, 80 C 480 w
page 5 of 10 function specification (continued) circuit block diagram for tib 480 output characteristic characteristic: output voltage vs output current for overload conditions until switch off after 4 s at nominal input voltages http://www.tracopower.com tib series, 80 C 480 w
page 6 of 10 output characteristic (continued) derating: max load vs input voltage derating: load vs ambient temperature http://www.tracopower.com tib series, 80 C 480 w
page 7 of 10 outline dimensions tib 080: m o d e l i n d u s t r i a l p o w e r s u ppl y 80 w v a d j . 24 v d c / 3. 4 a 100 - 2 4 0 v a c , 5 0 - 6 0 h z 2. 00- 0 . 9 0 a d c o n d c o k l n * measurement from fron panel to din-rail 98,6 1 * 94,2 1 32 1 6,35 m3 combi head 6,35 m3 combi head weight: 367g (12.95 oz) 114,2 1 din-rail hook tib 080-124 m o d e l i n d u s t r i a l p o w e r s u ppl y 80 w v a d j . 24 v d c / 3. 4 a 100 - 2 4 0 v a c , 5 0 - 6 0 h z 2. 00- 0 . 9 0 a d c o n d c o k l n tib 080-124 alternative side mounting: http://www.tracopower.com tib series, 80 C 480 w
page 8 of 10 outline dimensions tib 120: m o d e l i n d u s t r i a l p o w e r s u p p l y 1 2 0 w v a d j . 2 4 v d c / 5 a 1 0 0 - 2 40 v a c , 5 0 - 6 0 h z 1 .5 0 - 0 . 7 8 a d c o n d c ok l n * measurement from fron panel to din-rail 118,6* 114,2 36 1 6,35 m3 combi head 9,5 m3 combi head 124,2 1 din-rail hook tib 120-124 weight: 461g (16.26 oz) alternative side mounting: m o d e l i n d u s t r i a l p o w e r s u p p l y 1 2 0 w v a d j . 2 4 v d c / 5 a 1 0 0 - 2 40 v a c , 5 0 - 6 0 h z 1 .5 0 - 0 . 7 8 a d c o n d c ok l n tib 120-124 http://www.tracopower.com tib series, 80 C 480 w
page 9 of 10 outline dimensions tib 240: m o d e l i n d u s t r i a l p o w e r s u ppl y 2 4 0 w v a d j . 24 v d c / 1 0 a 1 0 0 - 240 v a c , 5 0 - 6 0 h z 2 . 8 9 - 1 . 2 7 a d c o n d c ok l n tib 240-124 * measurement from fron panel to din-rail 118,6 1* 114,2 1 48 1 6,35 m3 combi head 9,5 m3 combi head 124,2 1 din-rail hook weight: 643g (22.68 oz) alternative side mounting: m o d e l i n d u s t r i a l p o w e r s u ppl y 2 4 0 w v a d j . 24 v d c / 1 0 a 1 0 0 - 240 v a c , 5 0 - 6 0 h z 2 . 8 9 - 1 . 2 7 a d c o n d c ok l n tib 240-124 http://www.tracopower.com tib series, 80 C 480 w
www .tracopowe r. com ? copyright 2017 traco electronic ag sp ec i?cati ons can be changed wi thout noti ce! page 10 of 10 outline dimensions tib 480: m o d e l i n d u s t r i a l p o w e r s u ppl y 4 8 0 w v a d j . 2 4 v dc/ 2 0 a 100 - 2 4 0 v ac , 5 0 - 6 0 h z 2 . 8 9 - 1 . 2 7 a d c o n d c o k g n d r e m o t e o n / o f f n l tib 480-124 * measurement from fron panel to din-rail 118,6 1* 114,2 1 82 1 6,35 m3 combi head 9,5 m2 combi head 124,2 1 din-rail hook m3 combi head 3,5 weight: 1018g (35.91 oz) alternative side mounting: m o d e l i n d u s t r i a l p o w e r s u ppl y 4 8 0 w v a d j . 2 4 v dc/ 2 0 a 100 - 2 4 0 v ac , 5 0 - 6 0 h z 2 . 8 9 - 1 . 2 7 a d c o n d c o k g n d r e m o t e o n / o f f n l tib 480-124 rev. december 01. 2017 tib series, 80 C 480 w


▲Up To Search▲   

 
Price & Availability of TIB080-124

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X